Automated Methane Monitoring Solution with Optical Gas Imaging

FLIR ADGiLE™

Modello: FLIR GF77f 25° + FLIR ADGiLE Analytics Vai alla pagina di supporto
product image

The FLIR ADGiLE™ system is an advanced methane detection solution designed to provide continuous and autonomous monitoring of gas leaks. Integrating over a decade of FLIR’s advanced Optical Gas Imaging (OGI) technology, ADGiLE enables operators to quickly identify and address methane emissions. This system significantly reduces the need for manual inspections, offering real-time alerts and visual insights that help users act swiftly to prevent hazards and maintain operational efficiency.

  • Continuous Operation – Day or Night

    Operating 24/7 for continuous monitoring of methane emissions. This continuous monitoring is critical for sites where emissions can occur at any time.

  • Enhanced Methane Visualization

    Advanced leak detection analytics to precisely visualize and pinpoint methane emissions, enabling you to detect leaks quickly and efficiently.

  • Advanced Situational Awareness

    Accurately distinguish between operational leaks and fugitive leak emissions to improve safety and operational efficiency.

Specifiche
Risoluzione IR
320 × 240 pixels
Sensibilità termica/NETD
<25 mK at 30°C (86°F)
Banda spettrale
Uncooled microbolometer: 7.0 µm to 8.5 µm
Dati ottici e immagine
Banda spettrale
Uncooled microbolometer: 7.0 µm to 8.5 µm
Campo visivo (FOV)
25° × 19°
Campo visivo (FOV) - Lunghezza focale
18 mm (0.71 in)
Distanza minima di messa a fuoco
Without MSX: 0.3 m (0.98 ft)
With MSX: 0.65 m (2.1 ft)
Frequenza immagine
30 Hz
Identificazione ottica
Automatic
Messa a fuoco
• One-shot contrast
• Motorized
• Manual
numero f
1.04
Pitch sensore
25 µm
Risoluzione IR
320 × 240 pixels
Risoluzione spaziale (IFOV)
1.4 mrad/pixel
Sensibilità ai gas [NECL]
CH4: <100 ppm × m
(ΔT = 10°C, Distance = 1 m)
Sensibilità termica/NETD
<25 mK at 30°C (86°F)
Misurazioni e analisi
Accuratezza
Range 1: -20°C to 80°C (-4°F to 176°F) ±3°C (±5°F)
Range 2: 0°C to 250°C (212°F to 482°F) / 0°C to 100°C (32°F to 212°F):±3°C / 100° to 250°C (212° to 482°F):±3%
Range 3: 100°C to 500°C (212°F to 932°F):±3%
Correzione della temperatura riflessa apparente
Based on input of reflected temperature
Correzione della trasmissione atmosferica
Based on inputs of distance, atmospheric temperature, and relative humidity
Correzione emissività
Variable from 0.01 to 1.0
Correzioni misurazione
Global object parameters
Ottiche esterne e Correzione finestre
Based on input of optics/window transmission and temperature
Range di temperature oggetto
Range 1: -20°C to 80°C (-4°F to 176°F)
Range 2: 0°C to 250°C (212°F to 482°F)
Range 3: 100°C to 500°C (212°F to 932°F)
Generali
Dimensioni [L × P × A]
Camera: 510 mm × 177 mm × 229 mm (20.1 in × 6.97 in × 9.02 in)
Control unit (external): 700 mm × 530 mm × 265 mm (27.5 in × 20.8 in × 10.4 in)
Mounting plate: 535 mm × 430 mm (21.06 in × 16.9 in)
Incluso
Thermal camera in protective housing
Extra cable glands for auxiliary cables
Control cabinet (incl. Edge PC)
Adapter bracket
Screw kit
Power/Com cable
Ethernet cable, RJ45
Cardboard box environmental housing fixed
Insert cardboard box environmental housing
Printed documentation including the username and password for log in to the web interface of the camera
Materiale alloggiamento
Aluminium
Peso
5.90 kg (13.0 lb)
Alimentazione
Alimentazione esterna
Compatible with IEEE 802.3af, IEEE 802.3at/PoE Plus
Assorbimento
21 W
Tensione esterna
PoE Class 4 (25 W)
Ambientali e Certificazioni
Correzione della trasmittanza obiettivo
Automatic, based on signals from internal sensors
Corrosione
Salty fog resistance: ISO9227, to 1000 hours
EMC
EN 55032:2015 Emission Requirements
EN 55035:2017 Immunity Requirements
FCC – Title 47 CFR Part 15:2019
ICES-001 Issue 4:2014
Protezione
IP67
Range di temperature di esercizio
-30°C to 50°C (-22°F to 122°F)
Range di temperature di stoccaggio
IEC 68-2-1 and IEC 68-2-2, -40°C to 70°C (-104°F to 158°F) for 16 hours
Umidità (esercizio e stoccaggio)
Relative humidity: from 5% up to 95%
Galleria immagini
Documenti correlati
Restrizioni all'esportazione

Restrizioni all'esportazione

Equipment described herein pertains to a European Union origin product that is controlled as dual-use item by the European Union government. (It may be subject to US Jurisdictions when in the United States or possessed by a US person and may require authorization to re-transfer to or share with a foreign person (not a US Person).